Título :  EVALUACIÓN DEL ACERO ESTRUCTURAL DE TANQUE DAÑADO POR CORROSIÓN, UTILIZANDO LA MECÁNICA DEL DAÑO
Autor :  CASANOVA DEL ANGEL, FRANCISCO
GAYTÁN LÓPEZ, MOISÉS
Fecha de publicación :  2-jul-2012
Resumen :  The mechanical behavior of steel corrosion damaged during a period of eight years
of operation tank was analyzed in this research work. As a first point we conducted a
review of the design of the tank by means of the classic formulation of the elastic
design. As a second point samples were taken from the steel used in the hull of the
tank and steel used for reinforcement of false Fund that supports the filter material in
the tank. These samples were made tests for metallographic and by observation of
the samples in the electron microscope, unable to determine the type of localized and
widespread corrosion and corrosion compounds formed due to the corrosion
protection coating used inside the tank since its construction. In the analysis by x-ray
Spectrometry X was identified and checked by the type of steel used: steel A-284-
degree C in the hull of the tank and steel A-36 in the false bottom reinforcing. Testing
voltage to each of the two types of steel, and with these tests determined effort of
stress to the yield steel damaged by corrosion, which compared to the effort of
tension steel reference without damage. Loss of tension in laboratory for steel 368.0
Mpa, A-36 for steel without damage to 312.0 Mpa, for steel corrosion, for the A-284-
grade C steel 295.9 Mpa and steel without damage to 237.6 MPa damage effort thus
obtained. In the formulation of continuum damage mechanics coupled with damage
by corrosion from the phenomenological point of view, values were obtained: for A-36
steel effort tension 302.7 Mpa and A-284-steel grade C 260.7 Mpa tension effort. As
the third point was the design of the tank filtration using commercial software design
SAP 2000 V.10.1 Advanced, with which it was observed the concentration of efforts in
the area of Union of the false bottom plate with the hull of the tank.
URI :  http://www.repositoriodigital.ipn.mx/handle/123456789/5776
Aparece en las colecciones: Maestría

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
MOISÉS GAYTÁN LÓPEZ.pdf 9.54 MB Adobe PDF Visualizar/Abrir

Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

Excepto si se señala otra cosa, la licencia del item se describe como Attribution-NonCommercial-NoDerivatives 4.0 International

Creative Commons

Más de este tema...

Capacidad Organizacional para el Cambio (OCC)

Por favor, use este identificador para citar o enlazar ...

La educación virtual en los inicios del sigl

Por favor, use este identificador para citar o enlazar ...

“ESTUDIO DE FACTIBILIDAD TECNOLÓGICA PARA

Por favor, use este identificador para citar o enlazar ...